Indicating Device for Switchgear

Indicating Device for Switchgear (Switch Status Analogue Indicator)

Introduction to Indicating Device for Switchgear
AB6000 indicating device for switchgear is multifunctional, indicating primary circuit analog diagram, switch status, breaker position, earthing switch position, and spring energy storage. These indicating functions can be freely combined as needed. As an integral part, the indicating device is used on the medium voltage switchgear. It will simplify the design of switchgear panel, beautify the panel layout, and brings improved safety performance and status indicating performance.

You only need to specify the model and provide the primary scheme diagram. Our indicating device can be used for ABB-UniGear ZS1, ZS2, ZS3.2 / Simens-NXAIR / Schneider-Nvnex / Tellhow-KYN28A medium voltage switchgears.

Technical Characteristics of Indicating Device for Switchgear
Service condition: -10 ℃ ~ 50 ℃, ≤ 95% RH
Temperature and humidity control start values​​: when the ambient temperature is below 5 ℃ or relative humidity greater than 85% RH (can also be specified by the user)
Dielectric strength: ≥ AC220V between the shell and terminal
Insulation: ≥ 100M between the shell and terminal
Starter voltage: ≥ 15% phase voltage
Blocking voltage: ≥ 65% phase voltage
Power consumption: 10W
Vibration: 10 ~ 55 ~ 10HZ, 2g, 1min
Analog display section
Power supply: DC110V, AC110V, DC220V, AC220V, DC230V, AC230V (provided by the user when ordering)
Operating current: <30mA

Functions of Indicating Device for Switchgear

Dynamic Simulation Diagram
According to the user’s primary scheme diagram and voltage level (40.5KV yellow, 24KV and 12KV red, 7.2KV blue) , we make the sticker and indicate the touch spots (such as circuit breakers, handcart position, earthing switches, stored-energy spring, etc.) with dynamic instruction module, building real-time dynamic indications to bring more intuitive, richer, and more accurate status information, which is displayed by the indicating device as follows:

1. opening (orcircuit) display
2. closing (or circuit) display
3. pre-opening, pre-closing flashing indication
4. earthing display
5. energy storage display
6. working position display
7. test position display
8. handcart movement dynamic display
9. circuit breaker, earthing switch misuse flashing prompt

The last two indications of the indicating device offers more information to the operator than the traditional display does. The opening and closing display and pre-flash prompts allow the AB models can completely replace the original closing indicator.

Voice Prompts
1. When the circuit breaker is in closed state, mistakenly pushing the handcart to working position will get the voice prompt for opening the circuit breaker.
2. When the earthing switch is in closed state, mistakenly pushing the handcart to working position will get the voice prompt for opening the earthing switch.
3. When the circuit breaker and the earthing switch are both in closed state, mistakenly pushing the handcart to working position will get the voice prompt for opening the circuit breaker and the earthing switch.
4. When power transmission is going on through the switchgear main circuit, people standing in front of the switchgear will get the voice prompt indicating that the switchgear main circuit has been charged. (this feature is only available on product with human sensing probe)

Operating Functions
1. opening and closing operations
2. energy storage operations
3. remote / on-site operation
4. lighting operation

Charged Indicator
1. LED striking voltage (KV), rated phase voltage × 0.15-0.65
2. Latching striking voltage (KV), rated phase voltage × 0.65 above
3. When the three phases are all uncharged, latching-off light is on, and electromagnetic lock is put into action.

Temperature and Humidity Analog Control Function
The indicating device may take 1-2 channel temperature and humidity sensor and output contact. On-site temperature and humidity values​​ can be displayed, and users can set upper and lower limits of the heating / dehumidification output based on their own needs, when the ambient temperature is ≥ 30 ℃, the heating will stop unconditionally to prevent overheating damage.

Temperature and Humidity Digital Control Function
The intelligent display device may take 1-2 channel temperature and humidity sensor and output contact. On-site temperature and humidity values​​ can be displayed, and users can set upper and lower limits of the heating / dehumidification output based on their own needs, when the ambient temperature is ≥ 30 ℃, the heating will stop unconditionally to prevent overheating damage.

Closing Circuit Voltage Value Display
Secondary circuit opening and closing voltage is an important parameter that determines whether the opening and closing are exactly done. This feature is provided by AB66 above products.

Measurements
With the indicating device, you can monitor the three-phase current, voltage, active power, reactive power, frequency, and electric quantity in 0.5 precision.

Contact, Cable Connector Temperature Measurement Function
Online measurement on contact, cable connector temperature in range of -20 ℃ ~ 125 ℃, and accuracy of ± 2 ℃.

Human Sensing Probe
When someone stands in front of the switch cabinet, the lighting within switch cabinet will automatically start. LCD backlighting is turned on. Voice prompts will act during power transmission. When the operator leaves, the above functions stop automatically.

Communication
This device has a RS485 interface with remote communication capabilities, and works with DSC control system.

Note: (1) the above contact signals are all from the auxiliary contact of the circuit breaker, and earthing switch can use limit switch contacts.
(2) all of the indicating lights of the intelligent display device are off during loss of power.
(3) during high-pressure test, all the terminals must be pulled out so as not to get burnt.
(4) matched charged sensor can be provided with the intelligent display device, and if users use their own electric sensors, the output short circuit current must reach 220μA ± 10%.

Model List of Indicating Device for Switchgear
AB6000~AB6300 Switchgear Intelligent Display Devices
Model AB 6000A AB 6100A AB 6200A AB 6300A AB 6300AR AB 6000B AB 6100B AB 6200B AB 6300B AB 6300Z AB 6300ZC AB 6300ZR AB 6300ZCR
Function
Dynamic analog
diagram
Voice
prompt
                     
Charged
Indicator
and Lock
       
Fixed control of temperature and humidity                
Digital display
and control
of temperature
and humidity
                 
RS485
communication
interface
                   
Dimensions 139×199×25mm 139×192×58mm
Tapping Size 119×179mm 121×181mm
Note: temperature and humidity sensor standard wiring length is 3 meters, please specify if longer wiring length is required
AB6500~AB6800 Indicating Device for Switchgear
Model AB6500A AB6500B AB6600A AB6600B AB6703 AB6706 AB6709 AB6800A AB6800B
Function
Dynamic analog diagram
Voice prompt
Charged Indicator and Lock
Electricity and phase check    
Fixed control of temperature and humidity                
Digital display of
temperature and humidity
               
LED display of
temperature and humidity
               
LED display of temperature
and humidity point drop
     
Opening and closing, energy
storage, remote / on-site,
cabinet lighting operations
Pre-opening,
pre-closing flash instructions
Complete display of Opening and closing Cirucit
Voltage display of Opening and closing Cirucit      
Digital display of Opening and closing Cirucit      
Main circuit current, voltage,
power and other electrical
parameter testing and display
             
Electric quantity time
sharing billing functions
               
Contact, cable connector online
temperature measurement
function with infrared probe
        3 pcs 6 pcs 9 pcs    
Human sensing probe    
Optional feature: RS485 communication interface
Dimensions 238×178×83mm
Tapping Size 220×165mm
Note: temperature and humidity sensor standard wiring length is 3 meters, please specify if longer wiring length is required

Indicating Device External View and Tapping Size Drawing

AB6000~AB6300 Indicating Device for Switchgear
  • Front view
  • Rear view
  • Terminal view
  • Front view
  • Rear view
  • Terminal view

Note: The above photos, wiring drawings are for reference only.

AB6500~AB6800 Indicating Device for Switchgear
  • Front view
  • AB6500B terminal block rear view
  • Front view
  • AB6800B terminal block rear view

Note: The above photos, wiring drawings are for reference only.

We are a professional power distribution equipment manufacturer in China. To find the best power distribution solutions, just find us!